Spray Foam Insulation R-Value | Per-Inch Rates by Type

Spray foam R-value is R-3.5–R-3.8 per inch for open-cell and R-5.6–R-8.0 for closed-cell, with residential closed-cell typically at R-6.0–R-7.0.

Whether you’re insulating a 2×4 wall or topping off an attic to meet code, the spray foam insulation R-value you get depends on one choice first: open-cell or closed-cell. Open-cell foam delivers R-3.5 to R-3.8 per inch, while closed-cell foam ranges from R-5.6 to R-8.0 per inch, with most residential applications landing at R-6.0 to R-7.0. The table below shows what those numbers mean at real wall and roof thicknesses you’ll actually build.

Open-Cell vs Closed-Cell: What’s The R-Value Difference?

Open-cell spray foam consistently delivers R-3.5 to R-3.8 per inch regardless of how thick you spray it. Closed-cell foam delivers R-5.6 to R-8.0 per inch, with the exact number depending on density and formulation.

Open-cell is low-density foam that stays soft and flexible after curing. Its R-value holds steady at roughly R-3.6 per inch whether you spray it 2 inches deep or 11 inches deep. A standard 2×6 wall filled with open-cell hits roughly R-19 to R-21.

Closed-cell foam comes in medium-density (about 2 lb/ft³) and high-density (3 lb/ft³) versions. Medium-density closed-cell lands at R-6.0 to R-7.0 per inch — the most common range in residential work. High-density closed-cell reaches R-7.0 to R-8.0 per inch but costs more and is typically used in commercial or high-performance builds.

Calculating Spray Foam R-Value For Your Climate Zone

Divide your target R-value by the foam’s per-inch rating, and you get the thickness required. The formula works the same for any climate zone.

For a Zone 4A attic requiring R-60: closed-cell at R-7 per inch needs about 8.5 to 10 inches. Open-cell at R-3.6 per inch needs about 17 inches — more than double the depth. For a 2×6 wall targeting R-20: closed-cell needs roughly 3 inches, while open-cell needs about 5.5 inches, which fills the cavity completely.

Zone 5 roofs (parts of Ohio and Pennsylvania) require R-30 for new construction. Closed-cell at R-6.5 per inch reaches that in about 4.6 inches. Open-cell would need roughly 8.5 inches for the same target.

Thickness Open-Cell R-Value Closed-Cell R-Value
1 inch R-3.5–R-3.8 R-6.0–R-7.0
2 inches R-7.0–R-7.6 R-12–R-14
3 inches R-10.5–R-11.4 R-18–R-21
5.5 inches (2×6 wall) R-19–R-21 R-31–R-44
8.5–10 inches (R-60 attic) R-30–R-38 R-60
11 inches R-38 R-66–R-77
17 inches R-60

How Specific Products Compare On R-Value

Icynene’s product line shows how formulation changes the numbers. Their open-cell Classic and Classic Max deliver R-3.7 per inch — slightly above standard. The ProSeal closed-cell variant achieves R-21 in a single 3-inch pass, and the ProSeal LE can reach R-35 in a 5-inch pass. ArmorThane confirms closed-cell at R-6 to R-7 per inch across their standard formulations.

These product-level differences matter when you’re trying to hit a specific code requirement without overspraying. A builder needing R-21 in a 2×6 wall can use Icynene ProSeal at 3 inches and leave no cavity wasted. For homeowners taking on the job themselves, our roundup of the best closed cell spray foam kits for homeowners compares tested options by delivered R-value and coverage area.

Common Spray Foam R-Value Mistakes

The most frequent error is assuming open-cell can match closed-cell R-value without accounting for the thickness difference. Open-cell needs roughly double the depth to hit the same number — 17 inches versus 8.5 inches for R-60. That extra thickness eats into living space and adds framing cost.

Another mistake is treating all closed-cell foam as identical. Standard-density (2 lb/ft³) foam lands at R-6.0 to R-7.0 per inch, while high-density (3 lb/ft³) reaches R-7.0 to R-8.0. Specifying the wrong density leaves R-value on the table or wastes money on performance you don’t need. Johns Manville’s spray foam R-value breakdown explains how density drives the per-inch rating.

Using open-cell in foundations or rim joists is the third common error. Open-cell is permeable and cannot block moisture. Closed-cell acts as a Class II vapor barrier and is mandatory in below-grade and rim-joist applications.

When Does Closed-Cell Make More Sense Than Open-Cell?

Closed-cell wins wherever moisture protection, structural strength, or high R-value in a thin cavity matters. Open-cell wins where budget, sound dampening, or filling an irregular cavity is the priority.

Closed-cell adds structural strength to walls and roofs — open-cell is softer and flexible. Closed-cell maintains its R-value across all outdoor temperatures, unlike rigid polyiso boards that drop to R-4 to R-4.5 in cold weather. Open-cell costs roughly one-third of closed-cell, making it the budget-friendly choice for attics and interior walls where moisture isn’t a concern.

Condition Recommended Foam Why It Wins
2×4 walls (R-20 target) Closed-cell Exceeds code in 3.5-inch cavity
2×6 walls Either Open-cell fills at R-19, closed-cell hits R-30+
Attic (R-60 target) Closed-cell Needs 8.5–10 inches vs 17 for open-cell
Foundation walls Closed-cell Acts as moisture and vapor barrier
Rim joists Closed-cell Moisture barrier required by code
Sound dampening priority Open-cell Better acoustic absorption
Tight budget Open-cell Costs about one-third of closed-cell

The R-Value Numbers That Matter For Your Build

For most residential projects, the practical range is narrow. Target R-60 for attics in Climate Zone 4, R-20 for walls, and use closed-cell whenever moisture is a factor. Open-cell works fine for interior walls and cathedral ceilings where a vapor barrier isn’t needed, but plan for the extra depth.

The three numbers to remember: R-3.6 per inch for open-cell, R-6.5 per inch for standard closed-cell, and the formula — target divided by per-inch rating equals the inches you need. That’s the whole calculation.

FAQs

Does spray foam lose R-value over time?

Spray foam maintains its R-value for the life of the building when properly installed. Unlike fiberglass batts that can settle or lose loft, spray foam is chemically stable and does not degrade with age. The R-value you measure on day one is the R-value you still have a decade later.

Which spray foam has the highest R-value per inch?

High-density closed-cell foam (3 lb/ft³) delivers the highest per-inch R-value at R-7.0 to R-8.0. Standard closed-cell (2 lb/ft³) follows at R-6.0 to R-7.0. Open-cell foam is the lowest at R-3.5 to R-3.8 per inch.

Is R-19 spray foam good for a 2×6 wall?

R-19 meets minimum code for a 2×6 wall in most climate zones, but R-20 or higher is increasingly common. Open-cell spray foam in a 5.5-inch cavity delivers R-19 to R-21, which passes code. Closed-cell in the same cavity delivers R-31 to R-44, far exceeding requirements.

Does spray foam R-value depend on temperature?

Spray foam holds its rated R-value across all outdoor temperatures. This is a significant advantage over rigid polyiso boards, which drop to R-4 to R-4.5 per inch in cold weather. Spray foam at R-6.5 stays R-6.5 whether it’s 90°F or 10°F outside.

Can you spray too much foam and hurt R-value?

No. Spray foam’s R-value scales linearly with thickness. Too much foam wastes material and money, but it does not reduce the insulation performance. The risk is overshooting your target and paying for thickness you don’t need, not damaging the R-value.